Min kontaktperson
igus® ApS

Lysholt Alle 8

DK – 7100 Vejle

+45 86603373
+45 86603273

Special cables

chainflex® special cables are cables for special applications such as hanging applications, for use in rail vehicles or thermal and compensation cables. Use our comprehensive knowledge about cable plus the experience of 2 billion test cycles that are annually realized in the company-owned chainflex® laboratory. The steadily growing product range of the chainflex® special cables is based on the requirements of our customers. igus® also manufactures cables for special applications and uses a wide range of materials and manufacturing processes. Depending on the design, customer-specific special products can be made from lengths of 500 m.
We look forward to hear about your job definition!
 

 

Kategorier
Filtrer
Ledningskrav
Cable structure
Requirements

På grund af den store ordretilgang er leveringstiden for de enkelte varer midlertidigt 10-15 arbejdsdage længere end angivet. Ved produktions- eller maskinstop er i velkomne til, at kontakte os for hurtigere levering:

Antal produkter: 6

chainflex® CFTHERMO thermocouple cable

  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
fra 5,32 USD/ft
4 produkter, hvoraf klar til afsendelse:
3 24 - 48 timer
Til produktsiden
UV resistance
Medium Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 EAC
Certified to no. TC RU C-DE. ME77.B.01254 CTP
Certified to no. C-DE.PB49.B.00416 Lead free
Following 2011/65/EU (RoHS-II) Clean room
According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1 CE
Following 2014/35/EU

chainflex® control cable for rail vehicles CFSPECIAL.414

  • Requirements: For heaviest duty applications in rail vehicles
  • Outer jacket: Special mixture
  • Flame retardant
  • Halogen-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 60811-2-1
  • Toxicity: Low toxicity according to EN 50305-9.2
  • Smoke gas density: Low smoke gas density according to EN 61034-2
fra 4,25 USD/ft
2 produkter, hvoraf klar til afsendelse:
2 24 - 48 timer
Til produktsiden
UV resistance
High Flame retardant
Flame-retardant (following DIN EN 60332-1-2, DIN EN 45545-2) Fire safety class: 3 (in accordance to EN 45545-2) or 4 (in accordance to DIN 5510-2) Halogen-free
Following EN 50267-2-1 Lead free
Following 2011/65/EU (RoHS-II) CE
Following 2014/35/EU Toxicity
Low toxicity according to EN 50305-9.2 Smoke gas density
Low smoke gas density according to EN 61034-2

chainflex® CFFLAT motor cable

  • Requirements: For heavy duty applications
  • Outer jacket: TPE
  • Bio-oil-resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV resistance: High
På forespørgsel
1 produkter, hvoraf klar til afsendelse:
1 24 - 48 timer
Til produktsiden
UV resistance
High Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 EAC
Certified according to No. TC RU C-DE.ME77.B.01255 Lead free
Following 2011/65/EU (RoHS-II) Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 CE
Following 2014/35/EU

chainflex® PUR bus cable for hanging CFSPECIAL.182 applications

  • Requirements: For increased tensile load
  • Outer jacket: PUR
  • Overall shield
  • Bio-oil-resistant
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • PVC-free
fra 7,12 USD/ft
2 produkter, hvoraf klar til afsendelse:
1 24 - 48 timer
Til produktsiden
UV resistance
High Offshore
MUD-resistant following NEK 606 - status 2009 Flame retardant
According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1 Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 50267-2-1 UL/CSA AWM
Style 10138 and 20233, 300 V, 80 °C NFPA
Following NFPA 79-2012 chapter 12.9 Lead free
Following 2011/65/EU (RoHS-II)

chainflex® PUR hybrid cable for axis 7 of CFSPECIAL.792 robots

  • Requirements: Especially for axis 7 on robots
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Notch-resistant
  • Flame retardant
fra 15,96 USD/ft
6 produkter, hvoraf klar til afsendelse:
4 24 - 48 timer
Til produktsiden
Offshore
MUD-resistant following NEK 606 - status 2009 Flame retardant
According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1 Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 UL/CSA AWM
Style 10258 and 20234, 1000 V, +80 °C<br />CFSPECIAL.792.012: Style 11323 and 21223, 1000 V, 80 °C NFPA
Following NFPA 79-2012 chapter 12.9 Lead free
Following 2011/65/EU (RoHS-II) CEI
Following CEI 20-35 CE
Following 2014/35/EU

chainflex® bus cable CFSPECIAL.484

  • Requirements: For heaviest duty applications in rail vehicles
  • Outer jacket: Special mixture
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-2-1
  • Flame retardant
  • Smoke gas density: Low smoke gas density according to EN 61034-2
  • Toxicity: Low toxicity according to EN 50305-9.2
  • Self-extinguishing
fra 7,21 USD/ft
1 produkter, hvoraf klar til afsendelse:
1 24 - 48 timer
Til produktsiden
UV resistance
High Flame retardant
Flame-retardant (following DIN EN 60332-1-2, DIN EN 45545-2) Fire safety class: 3 (in accordance to EN 45545-2) or 4 (in accordance to DIN 5510-2) Halogen-free
Following EN 60754 Lead free
Following 2011/65/EU (RoHS-II) CE
Following 2014/35/EU Smoke gas density
Low smoke gas density according to EN 61034-2 Toxicity
Low toxicity according to EN 50305-9.2

Konsultation

I would be happy to answer your questions personally

Photo
Jan Toft Sørensen

Teknisk Senior Konsulent

Skriv e-mail

Levering og vejledning

Personlig betjening:

Mandag til fredag fra 7:00 til 20:00.
Lørdag fra 8:00 til 12:00.

Online:

24h