- For heavy duty applications
- PVC outer jacket
- Oil resistant (following DIN EN 50363-4-1)
- Flame retardant
- Silicone-free
- chainflex® class: 5.5.2.1
chainflex® data cable CF211
igus-icon-lupe
igus-icon-lupe
igus-icon-lupe
1 of 3
Item no.
chainflex® CASE available
Typical application areas
- For heavy duty applications
- Light oil influence
- Preferably indoor applications, but also outdoor ones at temperatures > 5°C
- Unsupported travel distances and up to 100m for gliding applications
- Storage and retrieval units, machining units/packaging machines, handling, indoor cranes
Garanteret levetid i henhold til garantibetingelser
Mere information chainflex® garanti
* Mulighed for et større antal dobbeltslag - bed venligst om en tilpasset beregning.
Mere information chainflex® garanti
Dobbeltslag | 5 millioner | 7,5 millioner | 10 millioner | ||||
---|---|---|---|---|---|---|---|
Temperatur, | v max. [m/s] | a max. | Vandring | R min. | R min. | R min. | |
fra/til [°C] | ikke-understøttet | glidende | [m/s2] | [m] | [Faktor x d] | [Faktor x d] | [Faktor x d] |
+5 / +15 | 10 | 11 | 12 | ||||
+15 / +60 | 5 | 3 | 50 | ≤ 100 | 7,5 | 8,5 | 9,5 |
+60 / +70 | 10 | 11 | 12 |
Certificates and standards